| DC output Voltage, Current | 24V 0~1A |
| Ripple and Noise (20Mhz bandwidth) | <50 mV pk-pk |
| Output Regulation | (10 to 90% load variation) 2.5% |
| Parallel Operation | Output current characteristic suitable for parallel operation of max. 5 units |
| Efficiency | 88% |
| Adjustable Range for DC Voltage | 24 – 28 VDC |
| Input Voltage Range | 85~264VAC / 85-375 VDC @47-63 Hz |
| Impact Current | @ 115VAC 0.7A max @ 230VAC 0.4A max |
| Output Derating | At operation between 85...93 VAC / 85...130 VAC 20% |
| Overload Protection | Current limitation at 120% typ. foldback, automatic recovery |
| Hold up time | (115 VAC / 230 VAC) min. 15 ms / min. 125 ms |
| Safety Class, Case Protection | Degree of protection class 1, IP 20 |
| Working Temperature | – 10°C ~ +70°C |
| Dimension and Weight | 27(W) x 75(H) x 100(D) mm 0.14kg |